Most of the site will reflect the ongoing surgical activity of Prof. Munir Elias MD., PhD. with brief slides and weekly activity.

Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


Multigen RF lesion generator .

07-MAY-2016  NAHI ABDALLA AL-SHEIKH  61 YEARS SPONDYLOLISTHESIS L1-2, L3-4 WITH SEVERE STENOSIS L1-2 DOWN TO L4-5.

 

Anamnesis

bullet

The patient came to the clinic 22-December-2015 complaining of LBP for 15 years with right sciatica. Exacerbation of right sciatica the last 2 months down to the right gastrocnemius muscle with numbness of this area. She is a known hypertensive for 8 years in hypoten 100 mg once daily.

bullet

On examination: the patient is limping for 10 years with exaggerated scoliotic stance. SLRS was 90 degrees both sides without pain. There is weak dorsiflexion right foot -4/5. There is severe OA both knees with pain and limitation of flexion right knee.

bullet

The patient was sent for investigations and MRI lumbar spine showed severe stenosis L1-2 down to L4-5 with scoliosis and spondylolisthesis L1-2 and L3-4. Right knee synovitis with torn medial meniscus. Dynamic X-rays confirmed the data acquired with MRI.

bullet

The patient then came 30-April-2016 claiming that the right knee improved. and sent for cardio evaluation. MRI repeated 04-May-2016 which showed the same data as before in the lumbar spine.

bullet

Decompressive laminectomy of L1 down to the upper half of L5 was achieved. Foraminotomy both L1,2,3,4 and L5 roots was done.  Using Expedium spine system 10 monoaxial screws 6x45 and bended 2 rods, 15 cm length and cross connector medium, were used to have transpedicular correction and fixation of L1,2,3,4 and 5. Stimulation of screws before connecting them with 8V stimulation did not show any radicular responses.  All stages of surgery were guided with C-arm. Using MultiGen, stimulation of the right L3,4,5 roots was achieved with 2 V. A bipolar pulsed mode RF with 42 Celsius, 240 sec, 2 Hz and 20 msec duration to right L3,4,5 roots was achieved using 4 bended catheters 10 mm exposed length.  Routine closure of the wound.

bullet

Smooth postoperative recovery. The patient is sciatica free. The power of right foot normalized and she was sent to the ward.


MultiGen

 

Comments  

bullet

This is the 55th case using the BPRF mode with MultiGen. This procedure regained routine acceptance  it became a usual part of the spine surgery. Click here for reference.

bullet

The patient has many problems which need surgical correction.

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

 


Back Up!

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map
 

© [2016] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved