Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
29-JULY-2002 ABEER JAMEEL AL-NAWAYSEH 24 YEARS
EXTRUDED DISC L5-S1 LEFT FORAMINAL OCCLUSION.
Anamnesis
The patient came to the clinic 27-July-2002
complaining of LBP for 3 months with left
sciatica after slipping from the table. MRI
lumbar spine performed 02-June-2002 showing
extruded disc L5-S1 with left foraminal
occlusion.
On examination: The patient in agonizing pain,
limping with exaggerated scoliotic stance.
Positive cough sign. SLRS
80 degrees left side with pain. There is weak
dorsi and planterflexion left foot-4/5.
Left S1 foraminotomy with removal of the
extrusion lateral to the axilla. Left sided
intradiscal cleaning L5-S1. The patient was put in
Reverse Trendelenburg position with Valsalva
maneuver and hyperventilation. No CSF leak.
Routine closure of the wound.
Smooth postoperative recovery.
The power of left foot improved.
She was sent to the ward.
Follow Up
The patient came to the clinic 11-August-2002
with clean wound and full power of the left
foot.
The patient came to the clinic 07-February-2013
complaining of neck and four limb pain with
morning stiffness. There was weak dorsi and
planterflexion left foot 4/5. She was sent for
investigations.
The patient then came 21-March-2013 with MRI
cervical done 07-March-2013 showing bulge C5-6.
Lumbar showing bulge L4-5 and L5-S1 with ESR 45
mm/h. The patient was treated conservatively.
The last time she came 18-September-2016 with
MRI showing I degree Arnold-Chiari with bulge
C5-6, 6-7. ESR still 45 mm/h. Conservative
treatment was advised.
Comments
There is still an estimated postoperative
recurrence around 7%.
The patient over the years will suffer
from other condition not related for his surgery.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .