Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
01-SEPTEMBER-2021 AFAF IZZAT NAJEEB 70 YEARS SEVERE
DORSAL CANAL STENOSIS D10-11, D11-12.
Anamnesis
The patient was operated by me
04-July-2019 for removal of the lower screws
penetrating the S1 roots. The patient then was
operated elsewhere with removal all of the
screws. The patient then came to the clinic 17-July-2021
with new MRI done 05-April-2021 bad quality not
informative. The patient then came
21-August-2021 complaining of LBP with
constipation and difficult micturition.
On examination, the patient is walking with help
of 2 persons. There is weak both iliopsoas
muscles 4/5 and both quadriceps 4/5, adduction and
abduction of the knees 3/5 with flail both feet
0/5 and
analgesia below both knees.
The patient was sent for investigations and
cardio consultation. MRI whole spine done
21-August-2021 showed severe stenosis D10-11 and
D11-12. Urine for CXS showed streptococcus spp, for what
Zinnat was started. It was agreed with the
family that surgery will help stop the process
of further deterioration.
New incision over the first
long one and skeletonization of D10, 11 and 12.
Decompressive laminectomy D10,11,12.
Foraminotomy D11. 12, L1 both sides. Inspection
of the disc of D11-12 both sides. The ligamentum
flavum was adherent to the dura in maximum
compression, for what sharp dissection was done
to avoid tear of the dura. Using MultiGen was
impossible due to severe adherence of the
ligamentum flavum to several areas. The patient was put in
Reverse Trendelenburg position with Valsalva
maneuver and hyperventilation. No CSF leak. A
piece of muscle tissue was used to cover the root
territory to minimize the postoperative scar
formation and prevent postoperative CSF leak. Routine closure of the wound. Smooth
postoperative recovery. The neurologic status
the same. She was sent to the ward.
FOLLOW UP
Too early now.
Comments
The stenosis was so severe that the
ligamentum flavum was adherent to the dura in several
places.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .