Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

01-APRIL-2004  AHMAD ALI AL-KILANI 27 YEARS MALPOSITIONED TRANSPEDICULAR SCREWS FOR STABLE FRACTURE.

 

Anamnesis

bullet

The patient came to the clinic 28-March-2004 telling that after RTA 6 months ago got fracture  L4, for what transpedicular screws were inserted 16-November-2003 elsewhere.

bullet

On examination: the patient is limping with exaggerated scoliotic stance. SLRS was 45 degrees both sides with pain. There is weak dorsi and planterflexion both feet 4/5 with weak left quadriceps muscle 4/5. The old and new requested investigations showed that the patient was essentially had stable fracture and was not in need for fixation and the inserted device was with a lot of mistakes, the upper screws in the L3-4 disc space and the lower ones inside the vertebral canal.

bullet

Considering that the construct only causing harm to the patient , the construct was exposed and there was no screw remover, for what drilling of the screws achieved the result. All the construct was removed. To avoid possible CSF leak from the screws insertion pieces of muscles were inserted to the cavities of the removed screws. Routine closure of the wound. Smooth postoperative recovery. The power of both feet normalized.

FOLLOW UP

bullet

The patient came to the clinic 14-April-2004 with clean wound and SLRS still 45 degrees both sides with pain, but no sensory nor motor deficit.

bullet

The patient then came several times and the last 15-October-2006 after performing MRI and LSS X-ray confirming normal alignment of the spine . He took report for legal purposes.

 

Comments

bullet

This case showing over use of transpedicular screws. Strict criteria must be followed to whom this must be used. At least do not do harm to the patient.

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

LooksCam II in the run.
LooksCam II Xenosys in the run  starting from  14-March-2021 with SheerVision TTL x4 magnification.


Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .


 

 

 

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map

© [2004] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved