Munir Elias 20-12-2013

Most of the site will reflect the ongoing surgical activity of Prof. Munir Elias MD., PhD. with brief slides and weekly activity. For reference to the academic and theoretical part, you are welcome to visit  neurosurgery.tv

Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

04-DECEMBER-2014  AHMAD MAHMOUD AL-KOOZ  23 YEARS POSTTRAUMATIC FRACTURE-DISLOCATION C3-4 WITH INTRADISCAL INJURY TO C4-5.

 

Anamnesis

bullet

The patient suffered RTA this morning without loss of consciousness with severe neck pain. He was admitted initially to Al-Bashir hospital and CT-scan of the brain was normal and CT-scan of the neck showed fracture dislocation C3-4. Cervical X-rays also confirmed this. The patient then was brought to Shmaisani emergency and MRI of the cervical spine showed the fracture dislocation with intradiscal injury of C4-5.

bullet

On examination, the patient in bed with soft collar fully oriented with severe neck pain. There weak left upper and lower limbs.

bullet

Discectomy of C3-4 was performed with insertion of Medtronic compact PEEK anatomical cage 14x11x4 mm. Intradiscal decompression of C4-5. Using Medtronic Atlantis plate 2 level 42.5 mm with 5 polyaxial screws 4x13 mm to C3 C5 and right side of C4 and one screw 4.5x13 mm to the left side of C5, fixation and reduction of C3-4-5 was achieved. All stages of surgery were guided with the C-arm Routine closure of the wound.

bullet

Smooth postoperative recovery. The power of the left side became better.

 

 

Comments  

bullet

The patient must be fused at these level to prevent future escalation of C4-5 intradiscal torn material.

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.

Leica HM500

Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014


Inomed MER system



Back Up!

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map
 