Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
16-MARCH-2003 AHMAD ALI ABU-AL-SUNDUS 62 YEARS
SEVERE CCS C3-4.
Comments
The recurrence rate in cervical disc is
zero.
Anamnesis
The patient came to the clinic 12-March-2003
complaining of numbness both hands and both legs
below the umbilicus with weak both upper limbs
with pain neck when rotating the head to all
direction. Dripping urine for 2 weeks. The
patient is hypertensive. MRI cervical spine
performed 08-March-2003 showing severe canal
stenosis C3-4, more from old extrusion C3-4 with
gliosis of the spinal cord.
On examination: the patient has neck pain
exacerbated with turning the head to all
directions. There is weak all muscles upper
limbs, more the right. All reflexes are
exaggerated with Hoffmann sign positive both
sides. Both lower limbs weak more the left with
spastic pattern and exaggerated deep reflexes
and Babinski positive both sides with clonus
both sides.
The patient was sent for investigations. There
is small osteophyte at the left corner of C5-6.
Dynamic studies showing overmobility of C4-5.
Transnasal intubation. Through
anterior approach,
discectomy C3-4 was achieved under the control of
C-arm. Using drilling the C3-4 calcified posterior
longitudinal ligament until the dura was seen under
the field. Routine closure of
the wound
Smooth postoperative recovery.
The radicular pain decreased and the power of four
limbs improved. He was sent to the ward.
Follow Up
The patient came to the clinic 01-April-2003
with clean wound with improvement of the power
of the four limbs with normalization of
sensation all over. The pathologic reflexes
still present.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .