Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
28-DECEMBER-2022 AHMAD SAMEER MUHAMED ABDALLA
31 YEARS HUGE RECURRENCE OF L4-5 MORE TO THE RIGHT WITH COMPLETE STENOSIS.
Anamnesis
The patient came to the clinic 17-May-2020 with
right sciatica for one year. He was operated
elsewhere 2018 for extruded disc L4-5 for right
sciatica. He was under treatment for epilepsy at
15 years age and stopped medication last 5
years. On examination at that time: MRI done
29-January-2020 showing broad based extrusion
L4-5. He was not limping with minimal scoliotic
stance. SLRS was 70 degrees right side with
pain. The patient was sent for investigations
and was treated conservatively. The patient then
came 30-July-2022 telling that he was OK! until
got deterioration of his right sciatica the last
3 weeks with numbness of his right foot. MRI
done the same day showing huge recurrence of
L4-5 with complete stenosis at this level. He
was limping with severe exaggerated scoliotic
stance. SLRS was 30 degrees right side with
severe pain and 75 degrees left side with less
pain shooting to the right. He had weak
dorsiflexion right foot 4/5 with hypalgesia
right L5 territory. He was advised to undergo
surgery and given pain-killers. The patient is
obese with 124 Kg weight.
The patient
disappeared, but came 27-December-2022 urging
for surgery and MRI done the same day showing
the same huge extrusion.
The old incision was used
with slight extension up and down. Right L5 foraminotomy with
right sided removal of the extrusion lateral to
the axilla and right
sided cleaning L4-5 disc space. During
neurolysis there was longitudinal partial tear
medial to the axilla with the arachnoid scarous.
To avoid CSF leak, bipolar coagulation of this
part was applied. Using
MultiGen, bipolar stimulation of the right L5
root was responding even to 1.5 Volts. A bipolar
pulsed mode RF with 42 Celsius, 240 sec, 2 Hz
and 20 msec duration to the right L5 root
was achieved using 2 bended catheters 10 mm
exposed length. Further bipolar stimulation of
the right L5 root was responding to 1.1 Volts.
The patient was put in Reverse Trendelenburg
position with Valsalva maneuver and
hyperventilation. No CSF leak. The power of the
right
foot improved. He was sent to the
ward.
MultiGen
FOLLOW UP
Too early now.
Comments
The re-recurrence rate here is around 7%,
because the disc space is not shallow.
This is the 248th case using the BPRF mode
with MultiGen. This procedure regained routine acceptance.
It became a usual part of the spine and peripheral nerves
surgery. Click here for
reference.
It still unclear to evaluate the
differences of pre and post application motor responses. The
only sure thing that it tells that the electrodes did not
migrate during the procedure and the nerve is functioning
properly. The nerve responded to 1.5 Volts but improved moderately in motor stimulation after
performed BPRF to 1.1 Volts.
With accumulation of data, it became
clear that the irritated nerve with aberrant currents
running in the C fibers up, not only causing no change or elevation of
the required voltage to achieve motor response, but they could cause the preoperative
weakness. Ablation of such currents results in facilitation
of the motor response and improvement of function with
disappearance of pain.
It is unclear why the roots have several
motor response with different patients, despite the fact
that the neurological status was the same and the anesthesia
protocol also the same.
It could be that the nerve is recovering
minute by minute after decompression and this can explain
why the motor conductivity is improving after the BPRF
application, which require 5 minute session in most cases.
After the 172d case, the elevation of
motor stimulation above 5 V was abandoned to avoid delayed
dural tear with subsequent CSF leak, which take place at the
contact at the lower electrode shaft with the dura below or
above the
level of the axilla.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Cios-Spin flat panel in the run.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .