th
   
   
 

Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

01-NOVEMBER-2002  ALI SHAWKAT FAYYAD 15 YEARS  PROGRESSING RIGHT EXTRADURAL HEMATOMA RIGHT TEMPORO-PARIETAL REGION.

 
 

Anamnesis

bullet

The patient admitted to Shmaisani hospital after suffering bicycle accident 30-October-2002 to the ICU conscious, moving four limbs with GCS 15/15. Urgent CT-scan showed small hematoma right temporo-parietal region with fracture of the right temporo-parietal bones.

bullet

The next day the patient started to show deterioration of his condition and repeat CT-scan showed enlargement of the extradural hematoma with mild shifting of midline structures, but still not in conning.

bullet

Osteoplastic craniotomy over the right temporal region and the hematoma was evacuated and strict hemostasis of the source of the bleeding. The bone flap returned to place. Routine closure of the wound

bullet

Smooth postoperative recovery. He was sent to the ward.

Follow Up

bullet

The patient came to the clinic 29-March-2003 complaining of intermittent headache left side with episode of epi attacks, which took place 1 month after accident. Epanutin started and sent for investigations.

bullet

The patient came 05-April-2003 with MRI of the brain done 01-April-2003, which was normal with EEG showing abnormal epi-activity, more to the right. The patient was asked to be followed for that, but he disappeared.

Comments  

bullet

It is better to avoid seeing the conning, but anticipate it and evacuate the hematoma to prevent further damage to the brain tissues.

 

 

 

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

LooksCam II in the run.
LooksCam II Xenosys in the run  starting from  14-March-2021 with SheerVision TTL x4 magnification.

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map