Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
06-OCTOBER-2002 AMIRA SULAYMAN AL-HNETI 35 YEARS
EXTRUDED DISC L5-S1 RIGHT SIDE.
Anamnesis
The patient came to the clinic
05-October-2002
complaining of LBP with right sciatica for 5 years.
She was seen by me at that time and advised for
surgery, but she refused. The the last 6 months
exacerbation of LBP. MRI lumbar spine done
28-July-1997 showing extruded disc L5-S1 right
and bulge L4-5. MRI repeated 12-June-2002
showing the same data.
On examination: The patient is limping, has LBP with
exaggerated scoliotic stance. There is weak dorsiflexion
right foot
3/5 and planterflexion right foot 4/5,
hypalgesia right S1 territory and SLRS was 45
degrees with pain right side. The right AJ is
absent.
Right S1 foraminotomy with
removal of the extrusion lateral to the axilla and
drilling of the osteophytes with right sided
intradiscal cleaning of L5-S1 disc space. The patient was put in
Reverse Trendelenburg position with Valsalva
maneuver and hyperventilation. No CSF leak.
Routine closure of the wound.
Routine closure of the wound.
Smooth postoperative recovery.
The power of the right foot normalized. She was sent to the ward.
Follow Up
The patient came to the clinic 17-October-2002
with clean wound and normal power and sensation
right foot. SLRS became 80 degrees without pain
in the right.
The patient then came 01-May-2006 telling that
after delivery, got left sciatica for 6 months .
MRI lumbar spine performed March-2003 ruled out
recurrence. She was limping in agonizing pain
with almost drop left foot and hypalgesia left
L5, S1 territories. She was given medications
and sent for investigations, but disappeared.
The patient then came 05-May-2020 telling that
the last 15 days got right sciatica. She was
limping. Motor power left foot 5/6, weak right
dorsiflexion 4/5. She was sent for
investigations and another time disappeared.
Comments
The estimated postoperative recurrence is
around 7% because the disc space is still not shallow.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .