Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
31-OCTOBER-2019 AMMAR ABED HNEISH 46 YEARS
EXTRUDED DISC C5-6 C6-7 WITH LEFT FORAMINAL OCCLUSION AND LEFT UPWARD MIGRATION.
Anamnesis
The patient came to the clinic 28-August-2019
complaining of neck and left upper limb pain for
40 days with numbness index left hand. MRI
cervical spine performed 09-July-2019 showing
extruded disc C5-6 and C6-7 with left partial
foraminal occlusion. On examination at that
time, he had weak extension left hand 4/5. He
had numbness of the left hand when turning the
head up. The patient was treated conservatively.
The patient then came 26-October-2019 telling
that he was doing well until the last 4 days,
when the same complain with more severe course
took place. The patient has no diabetes
mellitus, nor arterial hypertension.
On examination: the patient has weak extension
left hand -4/5 with pain when turning the head
up.
The patient was sent for investigations and MRI
of the cervical spine performed the same day
showing the same extrusion of C5-6, but the
extrusion of C6-7 progressed in size with left
upward migration.
Discectomy of C5-6, C6-7 was
achieved and the left side of C5-6 and C6-7 was followed
to achieve removal of the extruded pieces with
osteophytectomy until the dura was seen and
inspection of the roots to rule out any residual
extrusion or compression. EOS cervical cages
14x17x6.5 filled with IN'OSS bone graft were
inserted to both disc cavities. OSImplant
cervical plate 44 mm length and 6 plate screws
4x16 mm ( 2 fixed and four variable) were used.
All stages were
guided with C-arm. Routine closure of the
wounds.
Smooth postoperative recovery.
He was sent to the ward.
Comments
The patient progressed more severe pain after
trail of conservative treatment and the disc of C6-7 progressed
in size mandating surgical intervention.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .