Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

01-JULY-2002  BANDAR HMOUD AL-NAYEF  28 YEARS  REMOVAL OF SLIPPED HARRINGTON RODS.

 
 

Anamnesis

bullet

The patient after RTA 07-May-2001 got fracture dislocation L1 for what he was operated by me 10-May-2001 using Harrington rods with sublaminar wires. He was doing well until he felt that the rods are broken. X-ray performed recently showing dislodgment of the upper hooks out of the construct.

bullet

On examination: The patient is neurologically free except for unpleasant sensation of the movement of the construct.

bullet

The old wound refreshed and the rods with hooks and sublaminar wires were removed. Routine closure of the wound.

bullet

Smooth postoperative recovery. He was sent to the ward.

Follow Up

bullet

The patient came to the clinic 11-July -2002 with clean wound.

bullet

The patient then came to the clinic 20-January-2007 complaining of LBP and left knee pain. He was sent for investigations and MRI lumbar showing the old wedged fracture of L1 and MRI of the left knee showed torn lateral meniscus left knee. He was sent to orthopedic surgeon.

Comments  

bullet

The Harrington rods are presumed to be temporary installed until the healing of the bones. After 8-12 months it is advisable to be removed even without breaking or dislodgment.

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

LooksCam II in the run.
LooksCam II Xenosys in the run  starting from  14-March-2021 with SheerVision TTL x4 magnification.

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map

© [2002] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved