Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
23-NOVEMBER-2002 BASSAM MAHMOUD MUAWED
39 YEARS EXTRUDED DISC L4-5 WITH RIGHT DOWNWARD MIGRATION.
Anamnesis
The patient to the clinic
19-November-2002
complaining of LBP for 4 years with exacerbation
of right sciatica last 2 months. MRI lumbar spine done
22-October-2002 showing
huge disc L4-5 with right downward migration.
On examination: The patient in agonizing pain,
limping with exaggerated scoliotic stance.
SLRS
10 degrees
with pain in the right and 70 degrees in the
left shooting to the right. There is severe weak dorsi planterflexion
right foot 3/5, with hypalgesia right
S1 territory.
Right sided L5 foraminotomy, right hemiflavotomy with removal of the
extrusion lateral to the axilla from the
right in 2 big pieces. Right sided intradiscal cleaning L4-5.
Osteophytectomy done using drilling. The patient was put in
Reverse Trendelenburg position with Valsalva
maneuver and hyperventilation. No CSF leak.
Routine closure of the wound.
Smooth postoperative recovery.
The power of the right foot improved.
He was sent to the ward.
Follow Up
The patient came to the clinic 04-December-2002
with clean wound and normal power and sensation
right foot with
SLRS 80 degrees right side without pain.
The patient came several times and given sick
leave and the last time came 23-February-2009
with LBP without sciatica with normal power and
sensation of both feet and SLRS 70 degrees with
pain left side. Treated conservatively.
Comments
There is still an estimated postoperative
recurrence around 7%, because the disc space is still not
shallow.
The camera man is very talkative but even
not for second pay attention to the focus of the camera. In
the future such person must be kept away from activity.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .