Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
31-JULY-2024 FAWZI SALMAN AFDAL 51 YEARS RECURRENT
ANAPLASTIC ASTROCYTOMA G IV RIGHT CEREBELLAR HEMISPHERE.
Anamnesis
The patient an Iraqi citizen was operated by me
04-April-2017 for huge anaplastic glioma
Grade IV. The patient then underwent radiation
and chemotherapy. Several check MRI were
negative for recurrence. The patient noticed
ataxia 1 month ago for what MRI done, showing
recurrence of the tumor in the right cerebellar
hemisphere.
Using the setting position,
the wound was opened and the same craniotomy was
reflected down. The tumor was resected according
to MRI data and the anatomical landmarks, such
as the floor of the fourth ventricle, the
aqueduct, the right foramen of Luschka and
the lateral wall of the right cerebellum. The
tentorium was full of scar, for what in was
impossible to evaluate. Insertion of SNoW
Surgicele to bed of the resected tumor. Routine
closure of the wound. The patient was sent to
the MRI suite and MRI with contrast was obtained
and showing 5% of the tumor lateral to the
cavity and under the tentorium. The wound was
reopened in the supine position and dissection
of the cerebellum from the tentorium. That part
was resected up to the tentorium. Strict
hemostasis with reapplication of SNoW Surgicele. The bone flap was
closed and routine closure of the wound
. Smooth postoperative recovery. The patient was sent to the ICU.
FOLLOW UP
Comments
Even if you leave 5% of the tumor, since you
have intraoperative MRI, do it to be 0%.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .