Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
30-OCTOBER-2003 HAIFA JIBREEL AKKAWI 57
YEARS LCS L4-5 WITH BULGE DISC L4-5.
Anamnesis
The patient came to the clinic
16-October-2003 complaining of
LBP for 3 years with left sciatica for for 6
months with intermittent claudication and cannot
walk more than 20 meters. The patient is
hypertensive for 2 years in treatment. Operated
three time for thyroid 1985, in L-thyroxin 50
microgram daily. MRI bad quality done
26-September-2003 showing extruded disc L4-5
more to left with segmental stenosis.
On examination: the patient is in agonizing
pain, limping with exaggerated scoliotic stance.
SLRS was 90 degrees both sides without pain. There
is weak dorsi and planterflexion left foot
3/5 with
hypalgesia left S1 territory. The same noted in
the right foot, but to lesser extent. There is
still palpable hard mass in the thyroid region.
The patient was sent for new MRI which was done
19-October-2003 showing stenosis L4-5 with bulge
L4-5.
Decompressive laminectomy
L4-5. Foraminotomy both L5
roots was achieved. The
extruded disc material of L4-5 was removed from the
left
side of the axilla with left sided intradiscal cleaning L4-5 was achieved.
A free fat tissue piece obtained from the
subcutaneous layer obtained and transferred to
the root area to minimize postoperative
scarring. The patient was put in Reverse Trendelenburg
position with Valsalva maneuver and
hyperventilation. No CSF leak. Routine closure
of the wound.
Smooth postoperative recovery. The power of the
feet normalized.
FOLLOW UP
The patient
came to the clinic 09-November-2003 with clean wound
and no motor, nor sensory deficit.
The patient
then came 24-December-2004 complaining of LBP with
swollen left knee for 3 days. She was treated
conservatively for her knee problem.
Comments
There is still an
estimated postoperative recurrence around 7%
because the disc space not completely shallow.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .