Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
Anamnesis
The patient came to the clinic 10-January-2005
complaining of LBP with bilateral sciatica for
10 years with exacerbation the last year. He can
walk only 10-20 meters with intermittent
claudication. He is a known diabetic for 12
years. Dripping urine for 3 months. MRI lumbar
spine performed 22-May-2004 showing severe
lumbar canal stenosis L3-4 and L4-5.
On examination: The patient is in pain, limping with exaggerated scoliotic stance.
There is drop both feet with weak planterflexion
more the left foot. SLRS was 80 degrees both sides.
There is hypalgesia 20 cm above the ankles both
legs.
Extended decompressive
laminectomy L,4, upper half of L5 and lower half of
L2. Foraminotomy both L4 and L5 roots. The patient was put in
Reverse Trendelenburg position with Valsalva
maneuver and hyperventilation. No CSF leak. Routine
closure of the wound.
Smooth postoperative recovery.
The power of the feet still the same.
She was sent to the ward.
Follow Up
The patient came 16-March-2005 with slight
improvement of the power of the feet and
anesthesia of the feet at L5 territories
,feeling the dorsum of the feet.
Comments
The patient came with irreversible stage
of neural damage. The aim of surgery to stop escalation of
other complications.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .