Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
20-JULY-2003 HIYAM MAMOUD SULAYMAN 38 YEARS
RECURRENT DISC L4-5 WITH DOWNWARD MIGRATION.
Anamnesis
The patient came to the clinic 13-February-1999
telling that she was operated for disc surgery
13 months ago for lumbar disc with bilateral
sciatica more the right. MRI lumbar spine done
15-Novemeber-1997 showed extruded disc L4-5. She
is complaining of LBP with left sciatica with
neck and right upper limb pain. She was sent for
investigations including the whole spine. The
patient came 31-May-1999 with LBP and agonizing
left sciatica with MRI lumbar spine showing huge
recurrence of L4-5 with left downward migration.
On examination, the patient is in agonizing
pain, limping with exaggerated scoliotic stance.
There is hypalgesia left L5 and S1 roots with
almost drop left foot with weak dorsi and
planterflexion left foot3/5. SLRS was 30 degrees
with pain right side and 10 degrees left side
with more pain.
The part of the old incision
refreshed and scarolysis of the dura and
extended foraminotomy both L5 roots was
performed. Removal of the extrusion started from
the left, then bilateral cleaning of the disc
space of L4-5 was achieved. The patient was put
in Reverse Trendelenburg position with Valsalva
maneuver and hyperventilation. No CSF leak.
Routine closure of the wound.
Smooth postoperative recovery.
The power of left foot normalized. She was sent to the ward.
FOLLOW UP
The patient
came to the clinic 02-August- 2003 with clean wound
with hypalgesia left L5 root with weak dorsiflexion
big toe both feet more the left. SLRS was 45 degrees
right side and 30 degrees left with pain.
The patient
then came 20-March-2004 telling that the last 8
months still complaining of LBP with both hips pain.
SLRS was 80 degrees with minimal pain, hypalgesia
left S1 root with no motor deficit. The patient was
sent for investigations, but she did not perform
them.
The patient
then came 06-September-2004 complaining of
tonsilopharyngitis with pain left side of the face
and neck. She was sent for investigations but
disappeared.
Comments
The estimated recurrence rate
still ranking around 7%, because the disc space
still not shallow.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .