Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
19-APRIL-2002 IMAN MAHMOUD NASAR 23
YEARS UNSTABLE BURST FRACTURE D12.
Comments
In retrospective analysis, Harrington
rods fixation is an easy task, but it has cons and pros. It
is not MRI compatible. It needs 2 levels above and 2 levels
below the the fracture site. Disruption of the interspinous
ligament as in this case, prevent proper distraction.
Transpedicular fixation is superior to
this technique.
This analysis is documented 11-April-2021
and at this time there are a lot of options, you can choose
the best for the proper situation.
Anamnesis
The patient after falling down 2 days ago got
LBP with inability to walk, and she was admitted
to Shmaisani hospital. The patient is
neurologically free, but X-rays, CT-scan of the
spine and MRI showing unstable crushed D12
On examination: The patient in agonizing pain in
bed with Foley's catheter , but neurologically
free.
Skeletonization of D10 down
to L2, trying during that preserve the
interspinous ligaments, which was torn between
D12-L1 and the left lateral mass was destroyed.
Using Harrington distraction fixation rods,
fusion of L2 up to D10 was applied with control
for correction of the crushed body of D12, until
it got acceptable shape. Due to disruption of
the interspinous ligament a sublaminar wires
were added at D11 to provide more stability of
the construct. No CSF leak. Routine closure of the
wound.
Smooth postoperative recovery.
She was sent to the ward and ambulated the next
day.
Follow Up
The patient came to the clinic 29-April-2002
with clean wound walking and neurologically
free.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .