Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

19-APRIL-2002  IMAN MAHMOUD NASAR  23 YEARS UNSTABLE BURST FRACTURE D12.

Comments  

bullet

In retrospective analysis, Harrington rods fixation is an easy task, but it has cons and pros. It is not MRI compatible. It needs 2 levels above and 2 levels below the the fracture site. Disruption of the interspinous ligament as in this case, prevent proper distraction.

bullet

Transpedicular fixation is superior to this technique.

bullet

This analysis is documented 11-April-2021 and at this time there are a lot of options, you can choose the best for the proper situation.

Anamnesis

bullet

The patient after falling down 2 days ago got LBP with inability to walk, and she was admitted to Shmaisani hospital. The patient is neurologically free, but X-rays, CT-scan of the spine and MRI showing unstable crushed D12

bullet

On examination: The patient in agonizing pain in bed with Foley's catheter , but neurologically free.

bullet

Skeletonization of D10 down to L2, trying during that preserve the interspinous ligaments, which was torn between D12-L1 and the left lateral mass was destroyed. Using Harrington distraction fixation rods, fusion of L2 up to D10 was applied with control for correction of the crushed body of D12, until it got acceptable shape. Due to disruption of the interspinous ligament a sublaminar wires were added at D11 to provide more stability of the construct. No CSF leak.  Routine closure of the wound.

bullet

Smooth postoperative recovery.  She was sent to the ward and ambulated the next day.

Follow Up

bullet

The patient came to the clinic 29-April-2002 with clean wound walking and neurologically free.

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

LooksCam II in the run.
LooksCam II Xenosys in the run  starting from  14-March-2021 with SheerVision TTL x4 magnification.

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map

© [2002] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved