Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

06-MAY-2019  ISMAIL YASIN SAFI  32 YEARS  CRUSHED D8 AND D9 AFTER FALLING DOWN.

 
 

Anamnesis

bullet

The patient was transferred from other hospital after falling down at the morning without loss of consciousness. CT-scan of the brain was normal and CT-scan of the spine showed crushed fracture of D8 and D9 with fracture of the laminae of subsequent vertebrae. MRI performed showing compression at the fracture site with edema of the spinal cord.

bullet

On examination: the patient is neurologically free with ecchymosis of the right eye and the forehead.

bullet

Skeletonization of D6,7,8,9,10 and 11 was achieved with preservation of the ligaments between the posterior processes. The left D7-8 facet is fractured but acceptable for fixation. Using Xia 4 transpedicular screws at the level of D6,7,10,11 reduction and fixation of the spine was achieved. Screws all monoaxial 5.5mm X40 mm to D10 and D11. Screws 5.5mm x 35 mm to D7,6. Before inserting the rods, motor stimulation of the screws with 8 V did not show any response.  The left screw at D10 level showed CSF leak, which was explained by the injury, but it was stopped after inserting the screw. The fractured bones got acceptable alignment after that. Routine closure of the wound. The patient was given 1 unit blood the next day after surgery.

bullet

Smooth postoperative recovery. He was sent to the ward.

 

Comments  

bullet

The fracture is unstable and compressing the swollen spinal cord. Distraction-reduction of the fracture with subsequent stabilization is a must, to prevent further spinal cord damage.

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

 


 

Back Up!

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .

  

 

 

 

 

 

 

 

 

 

 

 

 

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map
 

© [2019] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved