Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
28-JULY-2004 JAMAL HASAN JABER 61 YEARS EXTRUDED
DISC C3-4 WITH SEVERE COMPRESSION OF THE SPINAL CORD.
Anamnesis
The patient came to the
clinic 28-April-2004 complaining of neck and LBP
for 10 years. Numbness four limbs for 1 year. Not diabetic nor hypertensive.
MRI lumbar spine done 04-November-2003 showing
huge extrusion L4-5 and cervical showing
extruded disc C3-4, 4-5. Brain MRI showing
scattered infarctions all over. The patient was
treated conservatively, then came 25-July-2004
with new MRI cervical spine done 22-July-2004
showing huge extruded disc C3-4 compressing the
spinal cord. Concerning the extruded disc of
L4-5, it was decided to resolve it after
eliminating the pressure effect at C3-4.
On examination, the patient
in agonizing pain, having neck pain when turning
the head to all directions. He has also LBP with
left sciatica. There is difficulty in walking. There is severe weak
grip and extension right hand 3/5 and right
triceps muscle 3/5. There is hypalgesia of the
ulnar distribution right hand.
Using the C-arm, the level of
C3-4 was identified and discectomy of C3-4 was
performed and the extruded pieces were removed until the dura was seen at the
bottom of the removed disc cavity. Routine closure
of the wound.
Smooth postoperative recovery. The power of the
four limbs dramatically improved.
FOLLOW UP
The patient
came to the clinic 07-August-2004 with clean wound
and still having mild weak left triceps muscle.
The patient
over the years came several times and there was
lipoma at the left side of the neck back. Then he
came 11-June-2010 with manifestations of Lumber
canal stenosis with MRI lumbar spine performed
08-June-2008 showing stenosis at L1-2. 2-3. 3-4 and
was given admission. Frozen right shoulder.
The patient
then came 06-July -2011 with new complans.
Comments
The recurrence rate
in cervical disc surgery is zero. Another disc
can cause de novo extrusion.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .