Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

27-JULY-2021  JUD WALEED SALAMAH 9 YEARS MALFUNCTIONING VPS.

 

Anamnesis

bullet

The patient was operated for hydrocephalus at KHMC when she was 6 months age. 3 months ago got nausea and vomiting and right paresis, for what she was diagnosed as having the distal part of the VPS was not functioning, She was operated elsewhere 04-July-2021 with revision of the distal part of the shunt. She improved, then a collection of CSF was noticed in the under the scalp, which was noticed before the revision. Her condition deteriorated for what she came to the clinic 24-July for evaluation.

bullet

On examination, the patient is is alert and irritable and check of the shunt reservoir showed non-functioning of the distal part of the shunt. The patient before coming here performed CT-scan of the abdomen 23-July-2021 showing loops at the right side of the abdomen with buckling, which is mostly the cause of the non-function. It was decided to totally replace the shunt with PS Medical VPS medium pressure adult type. The shunt for unknown reasons was inserted from the left side. The reservoir is located very low nearly at the neck area. There are 2 separate abdominal incisions in the left side of the upper abdomen.

bullet

The old VPS removed and replaced with new PS Medical medium pressure adult type VPS. Check for functioning was OK! and plain abdominal X-ray  was showing the shunt inside the abdomen. She was sent to the ward.


Reconstruction using ORS Visual showing 2 suspected areas of the defects.

FOLLOW UP

bullet

Too early now.

 

Comments  

bullet

When VPS start to troubleshoot, it is preferable to replace the whole unit with new one. You cannot be sure where is the defect of defects are located.

 

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

LooksCam II in the run.
LooksCam II Xenosys in the run  starting from  14-March-2021 with SheerVision TTL x4 magnification.