Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
09-NOVEMBER-2015 KHALED YOUSEF ABU-ARQUB 50 YEARS
EXTRUDED DISC L4-5 WITH RIGHT UPWARD MIGRATION.
Anamnesis
The patient came to the clinic 03-November-2015
complaining of LBP and right sciatica for 3 days
down to the lateral malleolus with positive
cough sign. The patient is a known diabetic for
4 months and with sarcoidosis with last attack
1997. He is under treatment with prednisolone 5
mg once daily until now.
On examination: the patient was limping with
exaggerated scoliotic stance. SLRS was 15 degrees
with pain right side. Weak dorsiflexion
right foot 4/5.
The patient was sent for investigations and MRI
done 04-November-2015 showed huge extruded disc
L4-5 with right upward migration. Dynamic
studies showed hint of mild spondylolisthesis
L4-5, which could be due to impaction of the
extruded disc right upward.
Foraminotomy right L5 root
with extension of the exposure far upward.
The right L4 root was severely compressed by the
extrusion The extrusion was removed lateral to
the axilla of L5 root.
Right sided intradiscal cleaning of L4-5 disc
space. Using MultiGen, a pulsed mode
RF with 42 Celsius, 240 sec, 2 Hz and 20 mesec
duration the right L4 root was achieved.
Routine closure of the
wound.
Smooth postoperative recovery. The power of
the right foot became normal without any sciatica. The patient was
sent to the ward.
MultiGen
Comments
The patient still has an estimated
postoperative recurrence around 7%.
This is the 16th case using the PRF mode
with MultiGen.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .