Multigen RF lesion generator .
05-JANUARY-2004 LATIFEH ABD-ELRAB SALEH 48 YEARS GIANT CONVEXITAL MENINGIOMA LEFT FRONTAL
REGION.
Anamnesis
The patient a Yemeni citizen came to the clinic
02-January-2004 complaining of severe headache
for 5 months with blurring vision and
progressing with time. MRI of the brain done in
Yemen showing giant meningioma left frontal
region with massive peritumoral edema.
On examination: The patient is alert but having
mild right sided hemiparesis. Motor and sensory
speech functions not affected, nor the olfactory
function.
Left wide osteoplastic
craniotomy over the left frontal area with
reflection of the bone flap to the left ear. The
dura was opened parallel to the wide matrix of
the meningioma and coagulation of the tumor and
piece-meal resection was achieved. After
debulking of the tumor, separation of the tumor
from the brain was proceeded with coagulation
and sharp dissection of the feeders. Radical
resection of the meningioma achieved. The fresh
frozen section was of meningioma. All the
running by side veins and arteries were
preserved. Lyodura was used to replace the
tumorous dura and water-tight stitching of the
lyodura was done after strict hemostasis. Routine closure
of the wound. Smooth postoperative recovery. The
power of the right side of the body became normal. She was
sent to the ward.
FOLLOW UP
The patient came to the clinic 15-January-2004
with clean wound and neurologically free. The
patient did not appear for follow up.
Comments
The estimated postoperative recurrence in this
case will be zero with good prognosis, since
total resection of the tumor was achieved.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .