Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
14-JULY-2002 MAHA JALAL BADDAR 41 YEARS
EXTRUDED DISC L5-S1 WITH RIGHT FORAMINAL OCCLUSION.
Anamnesis
The patient came to the clinic 06-July-2002
complaining of LBP for 3 months with right
sciatica. MRI
lumbar spine performed 06-May-2002 showing
huge extruded disc L5-S1 with right foraminal
occlusion.
On examination: The patient in agonizing pain,
limping with exaggerated scoliotic stance.
Positive cough sign. SLRS
70 degrees right side with pain. There is weak
dorsi and planterflexion right foot -4/5.
Right S1 foraminotomy with removal of the
extrusion lateral to the axilla. Right sided
intradiscal cleaning L5-S1. The patient was put in
Reverse Trendelenburg position with Valsalva
maneuver and hyperventilation. No CSF leak.
Routine closure of the wound.
Smooth postoperative recovery.
The power of the right foot improved.
She was sent to the ward.
Follow Up
The patient came to the clinic 27-August-2002
with clean wound and full power of the right
foot. SLRS was 75 degrees with pain.
The patient came to the clinic 19-April-2003
telling that the last 4 weeks got LBP for 3
days, then improved, then the last 5 days got
LBP with left sciatica. SLRS was 80 degrees with
pain in the left, but no motor, nor sensory
deficit. She was given medications and sent for
investigations, but disappeared.
Comments
There is still an estimated postoperative
recurrence around 7%.
The patient over the years will suffer
from other condition not related for his surgery.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .