Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
02-SEPTEMBER-2004 MAHMOUD ADEEB SALAMEH 30 YEARS SECOND RECURRENCE OF PLD L5-S1 LEFT SIDE.
Anamnesis
The patient came to the clinic 20-January-2004
telling that he was operated 7 months ago for
PLD L5-S1 for left sciatica without improvement.
MRI done 10-January-2004 showing huge recurrence
of L5-S1. He was unable to sleep horizontal due
to pain. He was operated for recurrence
21-January-2004. The patient then came
01-September-2004 complaining of severe LBP with
left sciatica. MRI lumbar spine done
09-July-2004 showing small recurrence and
advised for conservative treatment. He came
01-September-2004 urging for surgery.
On examination: The patient is limping with
exaggerated scoliotic stance. SLRS was 45
degrees in the right and 15 degrees in the
left with pain. There is
weak dorsi and planterflexion left foot 3/5 with hypalgesia
left L5 and S1 territories.
Foraminotomy
with neurolysis left S1 roots with
removal of the extrusion lateral to the axilla
from the left side. After
that, the root became lax and left sided
intradiscal cleaning L5-S1 disc space was done.
The patient was put in Reverse Trendelenburg
position with Valsalva maneuver and
hyperventilation. No CSF leak. A fat in pedicle was
transferred from the subcutaneous layer and
covered the exposed parts of the dura and roots
to minimize postoperative scarring. Routine
closure of the wound. Smooth postoperative
recovery. The power of the left foot became
normal.
He was
sent to the ward.
FOLLOW UP
The patient came to the clinic 13-Septmber-2004
with clean wound and SLRS 15 degrees left sides
with pain and normal power, but hypalgesia left
S1 root territory.
The patient came 19-October-2004 with new MRI
performed the same day showing no recurrence.
Comments
The estimated postoperative second re-recurrence is still
ranking around 7%, because the disc space is
still relatively not shallow.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .