Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

18-AUGUST-2002  MAHMOUD RAJAB AL-IZZA  47 YEARS  RECCURENT EXTRUDED DISC L2-3 MORE TO RIGHT.

 
 

Anamnesis

bullet

The patient came to the clinic 16-August-2002 complaining of LBP with right sciatica with weak dorsi and planterflexion right foot. He was operated elsewhere for PLD L2-3 10 years ago with little improvement.

bullet

On examination: The patient is in agonizing LBP with right sciatica with SLRS 45 degrees right side with pain. Weak dorsi and planterflexion right foot.

bullet

The patient was sent for investigations and MRI done showing still having huge extrusion L2-3 more to the right.

bullet

Refreshment of the wound and with slight extension up. During scarolysis a dural defect was seen at the upper border of the field and the root came up extradurally. It was left and covered by cotonoid and the patient was put in Trendelenburg position. The dura around the defect was expanded by drilling the bone circumferentially. Right L3 root neurolysis and removal of the disc of L2-3 lateral to the axilla. Intradiscal cleaning L2-3 from the right. After the dura and root became lax, the root was pushed back intradurally and the dural defect was closed by stitching by Nylon 4 zero. The patient was put in Reverse Trendelenburg position with Valsalva maneuver and hyperventilation. No CSF leak. Further inspection of the disc space from the right and the left side. Routine closure of the wound.

bullet

Smooth postoperative recovery. He was sent to the ward.

Follow Up

bullet

The patient came to the clinic 28-August-2002 with clean wound and dramatic improvement in his neurologic deficits.

Comments  

bullet

There is still a possibility for disc re-recurrence around 7%, because the disc space is not shallow.

 

 

 

 

 

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

LooksCam II in the run.
LooksCam II Xenosys in the run  starting from  14-March-2021 with SheerVision TTL x4 magnification.

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map

© [2002] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved