Most of the site will reflect the ongoing surgical activity of Prof. Munir Elias MD., PhD. with brief slides and weekly activity. For reference to the academic and theoretical part, you are welcome to visit  neurosurgery.tv

Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

30-SEPTEMBER-2015  MATUQA MUHAMED DABAAN  70 YEARS  SPONDYLOLISTHESIS L4-5 WITH SEVERE SEGMENTAL STENOSIS AT L3-4 AND L4-5.

 

Anamnesis

bullet

The patient came to the clinic 20-September-2015 complaining of neck and LBP for 8 months with inability to walk more than 100 meters. He had flue with cough for 2 days.

bullet

On examination: the patient was limping with exaggerated scoliotic stance. She has exposure keratitis left eye since childhood with severe impairment of vision of the left eye. There is edema both legs. There is pain when turning the head to the right and down. There is weak all muscles both upper limbs more the right. SLRS was 20 degrees with pain right side and 40 degrees with less pain left side. There is weak dorsiflexion both feet -4/5 and planterflexion right foot -4/5. Weak right quadriceps muscle 3/5.

bullet

The patient was sent for investigations and MRI cervical spine performed 20-September-2015 showing bulge all disci  with mild retrolisthesis C3-4. MRI dorsal was normal. Lumbar showed spondylolisthesis L4-5 with severe segmental stenosis at L4-5. Chest CT-scan was normal and dynamic studies showed the spondylolisthesis L4-5 and minimal at C3-4.

bullet

Transpedicular fixation with reduction of L3-4-5 using XIA 3 system with 6 monoaxial 6.5x45 mm screws with distraction between L4-5 5 mm and L3-4 3mm form the right side. Decompressive laminectomy L3,4 and upper third of L5 with foraminotomy L4 and L5 roots both sides. During decompression a small tear 2 mm at the upper right corner of the L3 level. It was repaired with 6 zero nylon. Check for CSF leak was negative. Using MultiGen , pulsed mode RF with 42 Celsius, 240 sec, 2 Hz and 20 mesec duration both L4 and L5 roots were manipulated.  42 mm cross connector was applied and Lifenet-Health allograft 15 cc mixed with mitted bone harvested from the patient was used and applied lateral to the rods. Routine closure of the wound.

bullet

Smooth postoperative recovery. The power of the feet became normal. No sciatica. The patient was sent to the ward.


MultiGen

 

Comments  

bullet

The patient has multiple problems, among them surgery was needed for the spondylolisthesis L4-5 with severe stenosis at L3-4 and L4-5.

bullet

This is the 8th case during which PRF was used.

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

 


Back Up!

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .