Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
29-JUNE-2003 MUHAMED SAEED AL-QARADI 33
YEARS BULGE C3-4 WITH EXTRUDED DISC C4-5 WITH LEFT FORAMINAL OCCLUSION.
Comments
The recurrence rate in cervical disc
surgery is zero.
Using plates and screws will provoke a
group of complications related to such technology, such as
extrusion of one of the screws. In this case it is not
significant, but in other cases it could need revision.
Anamnesis
The patient is a Yemeni citizen, came to the
clinic 27-August-2002 complaining of neck and
left shoulder pain for 4 years intermittent with
numbness of the entire left hand and the left
lower limb. MRI cervical spine done
20-August-2002 showing bulge C3-4 and extruded
disc C4-5 with left foraminal occlusion. The
patient was sent to perform MRI lumbar spine
which was done 28-August-2002 and was normal.
The patient was treated conservatively. The
patient then came 22-June-2003 telling that his
condition is deteriorating with numb both hands
and neck pain.
On examination: the patient having neck pain
when rotating the head all directions. There is
weak all muscles both upper limbs 4/5 except the
deltoids There is hypalgesia below the the C4
dermatome both sides.
Using the C-arm and transnasal
intubation, The level of C3-4 was identified and
discectomy of C3-4 and C4-5 was performed until the
dura was seen relax at the bottom of both removed
disci. Using Scitex 2 level plate with 6 screws,
fusion of C3-4-5 was achieved. Routine closure of
the wound
Smooth postoperative recovery.
The radicular pain decreased and the power of upper
limbs improved. He was sent to the ward.
Follow Up
The patient came to the clinic 02-July-2003 with
clean wound with no sensory or motor deficit.
The patient then came 18-December-2004 with
CT-scan performed 20-September-2004 showing
acceptable alignment of the construct with the
upper screw extruding for 2 mm. The patient is
neurologically free and sent for MRI cervical
which performed 19-December-2004 showing good
alignment and no spinal cord compression.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .