Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
07-DECEMBER-2003 MUHAMED YOUNES AL-AL-AMAYREH 68
YEARS GLIOBLASTOMA MULTIFORME LEFT PARIETO-OCCIPITO-TEMPORAL LOBES.
Anamnesis
The patient admitted to Shmaisani hospital
transferred from other hospital and he is
bedridden with Foley's catheter and not moving
four limbs with loss of sensation all over with
difficult evaluation of his visual function and
cannot obey commands. The condition started 2
months ago with rapid deterioration. MRI done
recently showing glioblastoma multiforme left
occipito-parieto-temporal lobes, shifting the
midline structures to the right.
Wide osteoplastic craniotomy
over the left occipito-parieto-temporal region
with reflection of the flap to the left ear. The dura was opened
and the cortex inspected for more safe
transcortical approach. The tumor was identified
and fresh frozen result was of glioblastoma
multiforme. Using the anatomical landmarks the
resection was proceeded until the posterior horn
of the left lateral ventricle and involved
choroid plexus were coagulated. he inferior horn
was also attacked to remove those parts of the
tumor. Inspection for remnant of the tumor
in the cavity for pathologic tumorous changes
were negative. Practical radical resection of
the visible either in the MRI or visual control
was achieved. The brain is lax and pulsating.
Strict hemostasis with routine closure of the
wound.
Smooth postoperative recovery
and the patient was sent to the ICU for 24 hours
observation.
FOLLOW UP
The patient came to the clinic 16-December-2003
with clean wound and has profound Anton
syndrome. He can walk with help. Radiotherapy
and chemotherapy was recommended.
The patient came 28-March-2004 with new MRI
done 16-March-2004 showing slight recurrence of
the tumor with big cavity. Radiotherapy
localized and WBR was performed. The patient
with the family were advised to repeat
investigations after 3 months, but they
disappeared.
Comments
The final histologic result was glioblastoma
multiforme. The prognosis is gloomy.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .