Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

25-JULY-2003  MUHAMED KHADER SALEM 22 YEARS SEVERE RUPTURE OF C5-6 WITH TETRAPLEGIA.

 

Anamnesis

bullet

The patient came to the Emergency of Shmaisani hospital after suffering RTA 1 day ago, transferred from other hospital with tetraplegia.

bullet

On examination, the patient is paraplegic with para-aneasthesia below C3 level with dysphonia and difficult breathing with collar in the neck and Foley's catheter. MRI cervical spine showing fracture far dislocation of C5-6.

bullet

The patient in supine position with the usual skull clamps with distraction force 10 KG was applied to reduce fracture. Exploration of the area showing that reduction is impossible without performing discectomy C5-6 and removing the bony elements obstructing the reduction. After acceptable reduction of the bony alignments, using Cloward instrumentation the huge sized caliber, a bone graft was obtained from the right iliac bone and fixed to 2 level Scientx cervical plate and fixation of C5-6 was performed. No CSF leak, denoting that the dura was not torn. Routine closure of the wound.

bullet

Considering that the patient was breathing with difficulty, he was put in ventilator and sent to the ICU.

FOLLOW UP

bullet

The patient was followed in the ICU and after performing check of the cervical spine it was found that the reduction is un-acceptable.

 

Comments

bullet

The condition of the patient is grave and in case of recovery with this case he will stay paraplegic.

 

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

LooksCam II in the run.
LooksCam II Xenosys in the run  starting from  14-March-2021 with SheerVision TTL x4 magnification.


Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .


 

 

 

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map

© [2003] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved