Most of the site will reflect the ongoing surgical activity of Prof. Munir Elias MD., PhD. with brief slides and weekly activity. For reference to the academic and theoretical part, you are welcome to visit
neurosurgery.tv
Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
26-SEPTEMBER-2015 MUHAMED WASEEM YOUNIS 30 YEARS
HUGE EXTRUDED DISC L4-5 WITH LEFT DOWNWARD MIGRATION.
Anamnesis
The patient came to the clinic 12-September-2015
complaining of left
sciatica for 2 months down to the left L5
territory. MRI lumbar spine done
05-September-2015 showing huge extruded disc
L4-5 with left downward migration.
On examination: the patient was limping with
exaggerated scoliotic stance.
SLRS was 60 degrees with pain left side. There is
weak dorsiflexion left foot 3/5.
Left L5 root foraminotomy
with removal of the extrusion lateral to the
root which was shifted medially. Left sided
intradiscal cleaning L4-5 disc space.
Subaxillary inspection for extrusion remnants.
The root is lax and free. Using MultiGen a
pulsed mode RF with 42 degrees Celsius, 240 sec,
2 Hz and 20 millisecond pulse width the left L5
root was manipulated using 2 curved catheters
above and below the axilla. Routine closure of the
wound.
Smooth postoperative recovery. The power of
the left foot became normal. No sciatica. The patient was
sent to the ward.
MultiGen
Comments
The patient still has an estimated
postoperative recurrence around 7%.
This is the 7th case during which PRF was
used. It seems that the sciatica disappearing and the
patients noticing the wound pain more than usual.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .