Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
07-FEBRUARY-2019 MUHANAD HUSAM ASHOOR 21 YEARS
EXTRUDED DISC L4-5 WITH RIGHT DOWNWARD MIGRATION.
Anamnesis
The patient came to the clinic 03-February-2019
complaining of LBP with right sciatica for 45
days down to the gastrocnemius muscle area. MRI
lumbar spine performed 31-January-2019 showing
huge extruded disc L4-5 with right downward
migration. There is sacralization of L5.
On examination: He is limping, with exaggerated
scoliotic stance. SLRS was
30 degrees right side with pain
and 80 degrees in the left without pain.
There was weak dorsiflexion
right foot 4/5.
Foraminotomy right L5 root with
reflection of the ligamentum flavum to the left to
preserve it. Subaxillary removal of the extrusion and right sided
cleaning L4-5 disc space. Using MultiGen, bipolar
motor stimulation of the right L5 root was achieved
with 1.9 Volts. A bipolar pulsed mode RF with 42
Celsius, 240 sec, 2 Hz and 20 msec duration to the
right
L5 root was achieved using 2 bended catheters 10 mm
exposed length. Further bipolar motor stimulation of
the right L5 root was achieved with 0.9 V with more
brisk response. The patient was put in
Reverse Trendelenburg position with Valsalva maneuver. No CSF
leak. The fat and ligamentum flavum were
repositioned in place. Routine closure of the
wound.
Smooth postoperative recovery. The power of
the right foot improved and the sciatica
disappeared.
He was sent to the ward.
MultiGen
Comments
There is still an estimated postoperative
re-recurrence around 7%, because the disc space height is
still not
shallow.
This is the 175th case using the BPRF mode
with MultiGen. This procedure regained routine acceptance.
It became a usual part of the spine and peripheral nerves
surgery. Click here for
reference.
It still unclear to evaluate the
differences of pre and post application motor responses. The
only sure thing that it tells that the electrodes did not
migrate during the procedure and the nerve is functioning
properly. Here the threshold of stimulation power of motor
stimulation of the affected dramatically improved after
BPRF.
With accumulation of data, it became
clear that the irritated nerve with aberrant currents
running in the C fibers up, not only causing no change or elevation of
the required voltage to achieve motor response, but they could cause the preoperative
weakness. Ablation of such currents results in facilitation
of the motor response and improvement of function with
disappearance of pain.
It is unclear why the roots have several
motor response with different patients, despite the fact
that the neurological status is the same and the anesthesia
protocol also the same.
It could be that the nerve is recovering
minute by minute after decompression and this can explain
why the motor conductivity is improving after the BPRF
application, which require 4 minute session in most cases.
After the 172d case, the elevation of
motor stimulation above 5 V was abandoned to avoid delayed
dural tear with subsequent CSF leak, which take place at the
contact at the lower electrode shaft with the dura below the
level of the axilla.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .