05-OCTOBER-2004 NANSY HANI YARVAS 46 YEARS
EXTRUDED DISC C5-6 RIGHT SIDE.
Anamnesis
The patient came to the
clinic 02-August-2004 complaining of LBP with
bilateral sciatica for 7 months. MRI lumbar
spine done 10-January-2004 showing bulge D11-12,
L3-4 and L4-5. She has migraine for 15 years.
On examination, the patient
in agonizing pain, having neck pain when turning
the head to all directions, more up and down. There is severe weak
grip and extension right hand 3/5 and both
triceps muscle 3/5. There is hypalgesia of the
middle finger right hand. There slight scoliotic
stance. SLRS was 85 degrees both sides with
pain. No myelopathic syndrome.
The patient was sent for
investigations and MRI cervical spine done
10-August-2004 showing huge extruded disc C5-6
and bulge C6-7.
Using the C-arm, the level of
C5-6 was identified and discectomy of C5-6 was
performed and the extruded pieces in the right
side were removed until the dura was seen at the
bottom of the removed disc cavity. Routine closure
of the wound.
Smooth postoperative recovery. The power of the
right upper limb dramatically improved.
FOLLOW UP
The patient
came to the clinic 16-October-2004 with clean wound
and neurologically free. Complaining of right
shoulder pain and given medications.
The patient
then came 28-February-2007 telling that she was
operated elsewhere for extruded disc L3-4
02-May-2005 and she came several times, the last
time 18-November-2017 with bilateral sciatica and a
lot of complains, that a lot of medications were
prescribed. She was sent for investigations and
disappeared.
Comments
The recurrence rate
in cervical disc surgery is zero. Another disc
can cause de novo extrusion.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .