Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
20-AUGUST-2018 NART MUHAMED KHEIR HATAQWAY 34 YEARS
RECURRENT EXTRUDED DISC L4-5 WITH LEFT DOWNWARD MIGRATION.
Anamnesis
The patient was operated by me
01-July-2018 for extruded disc L4-5. The
patient then came to the clinic 16-August-2018
complaining of LBP with left hip pain for 8 days
without sciatica.
On examination was not limping, nor having
scoliotic stance. SLRS was 80 degrees right side
and 70 degrees left side with pain.
There is no weakness.
The patient was sent for investigations and MRI
lumbar spine performed 16-August-2018 showing
recurrent disc L4-5 with left downward
migration. Other investigations were uneventful.
Neurolysis of the left L5 root
with removal of the downward extrusion and left sided
cleaning L4-5 disc space.
A trail to insert the
FIDES angular TLIF cage was performed from the same
side and it was not inserted, because it needs
transpedicular fixation. Otherwise without fixation
and compression, it will provoke pseudoarthrosis and
failed back syndrome. Using MultiGen, bipolar motor stimulation of the
left L5 root was achieved with 2.7 V. A bipolar pulsed mode RF with 42
Celsius, 240 sec, 2 Hz and 20 msec duration to the
left L5 root was achieved using
2 bended catheters 10 mm exposed length. Further
bipolar motor stimulation of the left L5 root
was achieved with 2.7 V. Routine closure of the
wound.
Smooth postoperative recovery.
He was sent to the ward.
MultiGen
Trail
to resolve the recurrence in lumbar disc surgery.
There is continuous effort to resolve the
recurrence without using transpedicular screws.
For 2 years I am trying to use the
SolidWorks,
CATIA and
Autodesk Inventor programs to construct the
perfect device to resolve such problem.
More than 30 versions were constructed and
seemed to be defective and not meeting the
intended requirements.
I used here the FIDES angular cage, so as to see
what are the problems which could face the intended
final device to make it perfect. The shaver
width must be 7-8mm width, the trail width also
must be not 10 mm, but 7-8mm. The curettes are
acceptable.
Comments
There is still an estimated postoperative
recurrence around 7%, because the disc space height is not
shallow.
This is the 164th case using the BPRF mode
with MultiGen. This procedure regained routine acceptance.
It became a usual part of the spine and peripheral nerves
surgery. Click here for
reference.
It still unclear to evaluate the
differences of pre and post application motor responses. The
only sure thing that it tells that the electrodes did not
migrate during the procedure and the nerve is functioning
properly. Here the
threshold of stimulation power of motor stimulation of the
affected root after application was the same.
With accumulation of data, it became
clear that the irritated nerve with aberrant currents
running in the C fibers up, not only causing no change or elevation of
the required voltage to achieve motor response, but they could cause the preoperative
weakness. Ablation of such currents results in facilitation
of the motor response and improvement of function with
disappearance of pain.
It is unclear why the roots have several
motor response with different patients, despite the fact
that the neurological status is the same and the anesthesia
protocol also the same.
It could be that the nerve is recovering
minute by minute after decompression and this can explain
why the motor conductivity is improving after the BPRF
application, which require 4 minute session in most cases.
The threshold of motor stimulation is
high because of the scar. Presence of scar elevate the motor
stimulation level 2-3 higher than the usual.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .