Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
05-JULY-2017 NASER MUHAMED KHLOOF 51 YEARS
EXTRUDED DISC L4-5 WITH RIGHT DOWNWARD MIGRATION.
Anamnesis
The patient came to Emergency Shmaisani hospital
04-July-2017 complaining of agonizing right
sciatica for 1 week. MRI performed 03-July-2017
showing extruded disc L4-5 with right downward
migration.
On examination, the patient is in agonizing
pain, limping with exaggerated scoliotic stance. SLRS
was 30 degrees with pain in right side. There is weak dorsi
and planterflexion right foot -4/5 with hypalgesia
right L5 territory.
The patient was sent for investigations and
dynamic studies ruled out overmobility and Lab
investigations were within normal limits.
Foraminotomy of the right L5
root was achieved. The extruded disk was removed
lateral to the axilla of the right L5 root.
Right sided intradiscal cleaning of L4-5 disc space was performed.
The right L5 root was inspected to rule out any
remnants of extrusion. Using MultiGen, bipolar motor stimulation of the
right L5
was achieved with 0.7 V. A
bipolar pulsed mode
RF with 42 Celsius, 240 sec, 2 Hz and 20 msec
duration to the right L5 root was achieved using
2 bended catheters 10 mm exposed length. Further
bipolar motor stimulation of the right L5 root was
achieved with 0.7 V.
Routine closure of the
wound.
Smooth postoperative recovery. The power of
the right foot normalized and he was sciatica free.
He was sent to the ward.
MultiGen
Comments
The patient still having an estimated
postoperative recurrence around 7%, because the disc
space is still not shallow.
This is the 124th case using the BPRF mode
with MultiGen. This procedure regained routine acceptance.
It became a usual part of the spine and peripheral nerves
surgery. Click here for
reference.
It still unclear to evaluate the
differences of pre and post application motor responses. The
only sure thing that it tells that the electrodes did not
migrate during the procedure and the nerve is functioning
properly. Here the
threshold of stimulation power of motor stimulation of the
right L5 root before and after application was the same.
With accumulation of data, it became
clear that the irritated nerve with aberrant currents
running in the C fibers up, not only causing no change or elevation of
the required voltage to achieve motor response, but they could cause the preoperative
weakness. Ablation of such currents results in facilitation
of the motor response and improvement of function with
disappearance of pain.
It is unclear why the roots have several
motor response with different patients, despite the fact
that the neurological status is the same and the anesthesia
protocol also the same.
It could be that the nerve is recovering
minute by minute after decompression and this can explain
why the motor conductivity is improving after the BPRF
application, which require 4 minute session in most cases.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .