02-NOVEMBER-2014 NASHAAT MAHMOUD MUSA 38 YEARS
HUGE RECURRENCE OF L5-S1 DISC WITH RIGHT FORAMINAL OCCLUSION.
Anamnesis
The patient was operated by me
22-November-2013 for extruded disc L5-S1
with right downward migration. The patient then
came 10-August-2014 complaining of LBP with
right sciatica for 2 months with weak
dorsiflexion right foot -4/5 and hypalgesia all
the right limb. He was limping with exaggerated
scoliotic stance with SLRS 45 degrees in the
right. The right quadriceps muscle was weak 4/5.
MRI dorsal and lumbar spine were requested. The
patient then came 25-October-2014 with MRI of
the lumbar spine done the same day showing
recurrence of L5-S1 disc with right foraminal
occlusion.
Refreshment of the old incision with exposure of
the right upper corner of the L5 lamina.
Neurolysis of the right S1 root. The extruded
disc was removed and further cleaning of disc
space of L5-S1. Inomed ISIS was used to study
the bad looking S1 root. It could response only
to 7 and above mA DNS.
Routine closure of the
wound.
Smooth postoperative recovery.
The power of the right foot became normal.
Comments
The patient still has an estimated
postoperative recurrence around 7%, because the disc space
still not completely shallow.
The healthy root must response to 1-2mA
DNS. This badly affected root was responding only to 7 and
above mA DNS, which must indicate the severe damage of the
nerve. The complete postoperative recovery of the power of
the foot immediately after surgery is in contradiction to
these data.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Inomed MER system
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .