03-JULY-2003 RABIHA HAMAD HUSSEIN 60
YEARS EXTRUDED DISC L4-5 WITH LEFT DOWNWARD MIGRATION.
Anamnesis
The patient came to the clinic
02-July-2003 complaining of LBP for 8 years with
exacerbation of LBP the last 2 months with
left sciatica the last 5 days. Thyroidectomy
done 1990 in no treatment.
On examination, the patient is limping with
exaggerated scoliotic stance. SLRS was 30
degrees right side and 25 degrees left side with
more pain. There
is almost drop left foot with weak
planterflexion 3/5 with hypalgesia left L5 and
S1 territories.
Left L4-5 hemiflavotomy with
foraminotomy left L5 root. The extruded disc was
removed lateral to the left axilla and left
sided intradiscal cleaning L4-5 was achieved.
The patient was put in Reverse Trendelenburg
position with Valsalva maneuver and
hyperventilation. No CSF leak. Routine closure of the wound.
Smooth postoperative recovery.
The patient showed improvement of the power of
her left foot.
She was sent to the ward.
FOLLOW UP
The patient
came to the clinic 12-July-2003 with clean wound
with SLRS right 80 degrees without pain and 45
degrees left side without pain. There is o motor or
sensory deficit.
The patient came several times and MRI lumbar spine
performed 26-June-2005 showing no recurrence, but
she is complaining of swollen right knee.
The patient the last time came 13-November-2014 with
many complains and MRI cervical done
12-November-2014 showing bulges all disci and MRI
lumbar spine showing spondylolisthesis L3-4 with
segmental stenosis. Dynamic studies showed II degree
spondylolisthesis L3-4. She was advised for fixation
and decompression, but she disappeared.
Comments
There is still an estimated postoperative
recurrence around 7%, because the disc space
is not shallow.
Over the long follow up the patient can suffer
from different problems not related to his
surgery, but deep in his brain he think there is
connection.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .