Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
17-JULY-2004 RASMIYEH MUHAMED UTHMAN 80 YEARS
SEVERE DORSAL CANAL STENOSIS D10-11 AND D11-12.
Anamnesis
The patient is my grandmother in law was
operated by me 13 years ago for extruded disc
L5-S1 for right sciatica and recovered. She
underwent CABAG operation 2 years ago. Then she came 07-July-2004 complaining of
back pain with inability to walk for 3 months
with progressing course.
On examination: The patient is limping
with exaggerated scoliotic stance. SLRS was 80
degrees both sides without pain. There weak all
muscles both lower limbs.
The patient was sent for investigations and MRI
lumbar and dorsal spine done 07-July-2004 showing severe
stenosis D10-11 and D11-12.
Decompressive laminectomy D11
and upper half of D12 and lower half of D10 with foraminotomy both
D11 and both
D12
roots was done. The disci of D10-11 and D11-12 were
inspected and right side removal of the
extrusion of D11-12 was achieved. Check for
instability was negative. The subcutaneous fat
was harvested with pedicle and transferred to
the dura to decrease the postoperative scar
formation.
Routine closure of the wound.
Smooth postoperative recovery. The power of
both legs became normal.
FOLLOW UP
The patient
came to the clinic 27-July-2004 with clean wound and
no motor nor sensory deficit. SLRS was
90 degrees both sides
without pain.
Comments
The lumbar canal stenosis when not progressing
and the patient in good shape, we put him under
observation, sine progress and deterioration
happens, surgery is mandatory.
With age different pathologies arise and must be
dealt accordingly.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .