Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

23-JUNE-2022  RIYAD MUHAMED AMEEN  38 YEARS  EXTRUDED DISC C6-7 WITH RIGHT FORAMINAL OCCLUSION.

 

Anamnesis

bullet

The patient came to the clinic 22-June-2022 complaining of severe neck pain with right upper limb pain for 3 days with numbness right hand.

bullet

On examination, the patient is in agonizing pain, with the head bended to the right shoulder. MRI done today showing huge extruded disc C6-7 with right foraminal occlusion. There is weak grip and extension of the right hand with the right triceps muscle 4/5. There is no myelopathic syndrome.

bullet

Using the C-arm. the C6-7 level was identified and discectomy of C6-7 was performed and the extrusion was removed, until the dura was seen at the entire bottom of the removed disc cavity. EOS OSImplant 7x14x17 mm dimensions was applied. Routine closure of the wound. Smooth postoperative recovery. The power of the right upper limb improved. He was sent to the ward.


EOS OSIMPLANT

FOLLOW UP

bullet

Too early now.

Comments  

bullet

Recurrence in cervical discectomy is zero.

 

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

LooksCam II in the run.
LooksCam II Xenosys in the run  starting from  14-March-2021 with SheerVision TTL x4 magnification. 

 
Cios-Spin flat panel in the run.

 

 

 


Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .


WELCOME TO AL-SHMAISANI HOSPITAL

 