Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
14-SEPTEMBER-2004 SAFI KHAMEES HASUNEH 63
YEARS INSTABILITY OF C3-4 WITH MALACIA OF THE SPINAL CORD.
Anamnesis
The patient came to the
clinic 11-September-2004 complaining of neck pain
for 7 months with numbness median distribution
both hands. He was operated elsewhere for right
CTS without effect. His condition is
deteriorating. MRI cervical spine done
05-June-2004 showing spondylolisthesis C3-4 with
compression of the spinal cord with bulge C5-6.
MRI cervical spine repeated 12-August-2004
showing worsening of the C3-4 area.
On examination, the patient
in pain, having neck pain when turning
the head to the right. The patient walking
shuffling, limping. There is severe weak
grip and extension both hands 3/5 and both
triceps muscles 3/5, so the deltoids and both
biceps brachii 4/5. There is hypalgesia of the
hands both sides. Hoffman positive both sides
with exaggerated deep reflexes four limbs. There
is weak muscles both lower limbs. Babinski
positive both sides.
Using the C-arm, the level of
C3-4 was identified and discectomy of C3-4 was
performed and the extruded pieces were removed until the dura was seen at the
bottom of the removed disc cavity. Using Scientx
one level miniplate, fusion of C3-4 was achieved. Routine closure
of the wound.
Smooth postoperative recovery. The power of the
four limbs dramatically improved.
FOLLOW UP
The patient
came to the clinic 22-September-2004 with clean wound
and more neurologic improvement. Check X-ray showed
good alignment of the construct.
The patient
came several times with further improvement, then he
came 26-April-2008 complaining of LBP with left
sciatica. MRI lumbar spine performed 27-July-2007
showing elements of lumbar canal stenosis. The
patient was sent for cervical check up and the right
upper screw was out 10 mm, but not bothering him.
Comments
The recurrence rate
in cervical disc surgery is zero. Another disc
can cause de novo extrusion. When instability is
the main cause, fusion is a must.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .