Most of the site will reflect the ongoing surgical activity of Prof. Munir Elias MD., PhD. with brief slides and weekly activity. For reference to the academic and theoretical part, you are welcome to visit
neurosurgery.tv
Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
09-AUGUST-2015 SALAH ABDO AL-KHATEEB 68 YEARS
EXTRUDED DISC L3-4 WITH BILATERAL DOWNWARD MIGRATION WITH SEVERE SEGMENTAL
STENOSIS.
Anamnesis
The patient came to the clinic 01-August-2015
complaining of LBP with right sciatica for 3
months not reaching below the right knee. The
patient is a known hypertensive for 20 years in
medication.
On examination: He was limping with exaggerated scoliotic stance.
SLRS was 10 degrees with pain right
side. There was weak dorsi and planterflexion right foot
-4/5.
The patient was sent for investigations and MRI lumbar spine performed
01-August-2015
showed extruded disc L3-4 with bilateral
downward migration and severe segmental stenosis. Dynamic studies
were negative for over mobility. He had gout for
what pain killers and Zyloric were prescribed.
The patient was sent for cardio and urologic
consultation.
Using the C-arm the L3-4 level was identified.
Decompressive laminectomy L3-4 with foraminotomy
right L4 root. Due to severe compression. there
was a dural defect at the axilla of the right L4
root lateral aspect about 1.5 mm. It was
repaired by nylon 4 zero. Discectomy L3-4 from
the right. The root became lax and free. A piece
of muscle was placed of the stitched dural
defect after performing the Valsalva procedure,
which was negative. Routine closure of the
wound.
Smooth postoperative recovery. The power of the
right foot became normal.
Comments
The patient still has an estimated
postoperative recurrence around 7% because the disc space
still not completely shallow.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .