Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
11-SEPTEMBER-2003 SALAMEH ABDALLA AL-SHAWARBEH
53 YEARS RECURRENT PLD L3-4 WITH DOWNWARD MIGRATION.
Anamnesis
The patient came to the clinic 09-September-2003
telling that he was operated 3 years ago for
PLD L3-4 for right sciatica then he started to
complain of left sciatica in January-2003, then
right sciatica the last 2 months.
Diabetic for 1 year in treatment. Cath done 7
years ago was normal.
On examination: The patient is limping with
exaggerated scoliotic stance. SLRS was 40
degrees in the right and 70 degrees in the
left with pain. There is
weak dorsi and planterflexion right foot 3/5,
weak right quadriceps muscle -4/5 and abduction
right knee 4/5..
The patient was sent for investigations and MRI
done the same day showing huge recurrent disc
L3-4 with right downward migration.
Foraminotomy
with neurolysis right L4 root with
removal of the extrusion lateral to the axilla
from the right side. After
that, the root became lax and right sided
intradiscal cleaning L3-4 disc space was done.
The patient was put in Reverse Trendelenburg
position with Valsalva maneuver and
hyperventilation. No CSF leak. A fat in pedicle was
transferred from the subcutaneous layer and
covered the exposed parts of the dura and roots
to minimize postoperative scarring. Routine
closure of the wound. Smooth postoperative
recovery. The power of the right foot became
normal.
He was
sent to the ward.
FOLLOW UP
The patient came to the clinic 21-Septmber-2004
with clean wound and SLRS 60 degrees both sides
with pain and normal power and sensation.
The patient came 04-December-2003 with new MRI
performed the same day showing recurrence L3-4
right side and advised for surgery, but he
disappeared.
Comments
The estimated postoperative second re-recurrence is still
ranking around 7%, because the disc space is
still relatively not shallow.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.