Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
09-SEPTEMBER-2003 SAMEEH HASAN AHMAD 57 YEARS
SEVERE CERVICAL STENOSIS C4-5, 5-6, 6-7 AND EXTRUDED DISC C7-D1.
Anamnesis
The patient came to the clinic 07-Sptember-2003
complaining of neck pain, left shoulder and
right upper limb pain for 40 days with weak both
lower limbs.
On examination: the patient limping with wide based legs gait. He has pain when
looking to all directions more to the left with
preserved deltoids. Below this level there is
deep tetraparesis with hypalgesia below C5
level. Urination preserved. MRI cervical spine
done before the visit showing severe cervical
canal stenosis C4-5, 5-6, 6-7 with malacia of
the spinal cord.
Discectomy of C4-5, 5-6 and
C6-7
was done until the dura was seen along all the
posterior aspects. Using Scientx cervical plate
bended to align with his natural curve with 8
screws, fusion of C4-5-6-7 was achieved. All stages of surgery were
done under C-arm control.
Routine closure of the wound.
Smooth postoperative recovery. The power of the
upper and lower limbs slightly improved.
FOLLOW UP
The patient
came to the clinic 18-September-2003 with clean wound
and the power of the four limbs normalized with
sensation limited to the left median distribution
and left D5-7 dermatomes.
The patient
then came 12-October-2003 for check up with X-ray
cervical showing good alignment of the construct.
The patient
then came 12-April-2015 complaining of numbness
both feet. The upper limbs
sensation and power became normal, and the power of
proximal muscles lower limbs 5/5. There is
hypalgesia both feet below the ankle with weak dorsi
and planterflexion right foot 4/5. The patient sent
for MRI lumbar spine, which performed
12-April-2015 showing lumbar canal stenosis L2-3,
3-4 and L4-5. He was advised for surgery.
Comments
The patient has
progressive cervical canal stenosis. The sooner
the surgical decompression, the better the
outcome.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .