24 AUGUST-2015 SAMIHA HASAN SHIHADEH 55 YEARS
DISKITIS OF L2-3 WITH OSTEOMYELITIS L2 AND L3 WITH INVOLVEMENT OF THE PARASPINAL
MUSCLES.
Anamnesis
The patient came to the clinic 23-August-2015
complaining of LBP with right sciatica for 2
years. Exacerbation of the LBP with numbness
right foot the last month. She underwent left
gluteal abscess drain 2 weeks ago after Voltaren
injection to that area. The CXS of the evacuated
abscess was E.Coli. MRI lumbar spine
performed 22-August-2015 showing diskitis of
L2-3 with osteomyelitis L2 and L3 with
involvement of the paraspinal muscles both
sides.
On examination: the patient is in agonizing
pain. The SLRS was 80 degrees both sides with
full power both legs and hypalgesia L5 and S1
both sides.
Using the C-arm, the level of L2-3 was
identified. A long needle was inserted to the
disc space L2-3 fro the left side using local
anaesthesia. A 3 ml pus was evacuated and sent
for all possible investigations.
The patient was sent to the ward.
Follow Up
The CXS became available 27-August-2015 showed
E. Coli which was sensitive to Amikacin and
Levofloxacin and no tumor, not fungi nor tbc
could be confirmed.
Comments
The patient has infection in the L2-3
area which hematologically came from the gluteal area. All
possible investigations must be considered in mind.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .