Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
21-JUNE-2025 SEHAM ODEH ISEED 72
YEARS EXTRUDED DISC L3-4 WITH BILATERAL FORAMINAL OCCLUSION.
Anamnesis
The patient was seen by me since 2003 for
several complains, among them convexital
meningioma right side , which was operated
elsewhere 2009. She is receiving Depakine chrono
twice daily for controlled epileptic attacks.
The patient then came 11-June-2025 complaining
of difficult walking for 2 months with LBP, numbness
both feet more the right with waddling
gait, varicous veins both lower limbs and pain
of the right knee.
On examination, SLRS was
80
degrees without pain right side and 85 degrees
in the left. There is weak dorsi and
planterflexion left foot due to old brain
surgery. No sensory deficit.
MRI lumbar spine , pelvis and right knee done the same day showing extruded
disc L3-4 with bilateral foraminal and
extraforaminal extrusion. The hips have
bilateral trochanteric bursitis with torn
meniscus right knee and extrusion of the
meniscus. CRP was negative, ESR 15 mm/h.
The level of L3-4 was
identified and L3 laminectomy, upper third of L4
and foraminotomy both L4 roots was done.
Right sided L3-4 disc cleaning was done with
removal of the extrusions piercing the root.
Inspection of the left side was negative. Using
MultiGen, bipolar stimulation of the right L4
root responded to 0.6 Volts. A bipolar pulsed
mode RF with 42 Celsius, 240 sec, 2 Hz and 20
msec duration to the right L4 root was
achieved using 2 bended catheters 10 mm exposed
length. Further bipolar stimulation of right L4
root responded to 0.5 Volts. Bipolar stimulation
of the left L4 root responded to 0.9 Volts. A
bipolar pulsed mode RF with 42 Celsius, 240 sec,
2 Hz and 20 msec duration to the right L4 root
was achieved using 2 bended catheters 10 mm
exposed length. Further bipolar stimulation of
left L4 root responded to 0.7 Volts The patient was put in Reverse
Trendelenburg position with Valsalva maneuver
and hyperventilation. No CSF leak. Routine closure of the
wound. The patient showed normal recovery. She was sent to the ward.
MultiGen
FOLLOW UP
Too early now.
Comments
The extruded disc was occluding bilateral
L3-4 foramen with extension extraforaminal.
This is the 286th case using the MultiGen. This procedure regained routine acceptance.
It became a usual part of the spine and peripheral nerves
surgery. Click here
for reference. The patient showed improvement of the motor
stimulation after BPRF, and the sciatic pain decreased in
the right leg.
With accumulation of data, it became
clear that the irritated nerve with aberrant currents
running in the C fibers up, not only causing no change or elevation of
the required voltage to achieve motor response, but they could cause the preoperative
weakness. Ablation of such currents results in facilitation
of the motor response and improvement of function with
disappearance of pain.
It is unclear why the roots have several
motor response with different patients, despite the fact
that the neurological status was the same and the anesthesia
protocol also the same.
It could be that the nerve is recovering
minute by minute after decompression and this can explain
why the motor conductivity is improving after the BPRF
application, which require 5 minute session in most cases.
After the 172d case, the elevation of
motor stimulation above 5 V was abandoned to avoid delayed
dural tear with subsequent CSF leak, which take place at the
contact at the lower electrode shaft with the dura below or
above the
level of the axilla.
Before doing motor stimulation in
peripheral nerve surgery with tourniquet. always release the
tourniquet before performing motor stimulation.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Cios-Spin flat panel in the run.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .