Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
18-JULY-2021 SHIRIN ADNAN AL-HINDI 49 YEARS
EXTRUDED DISC C6-7 WITH LEFT FORAMINAL OCCLUSION.
Comments
The extrude disc in cervical region
cannot recur, because all the disc material including the
extrusion is removed.
This is the 219th case using the BPRF mode
with MultiGen. This procedure regained routine acceptance.
It became a usual part of the spine and peripheral nerves
surgery. Click here for
reference.
MultiGen
Anamnesis
The patient came to the clinic 12-July-2021 with agonizing
neck and left upper limb pain with numbness
left median distribution. The patient was
operated by me
04-March-2010 for PCD C4-5. MRI cervical
spine done 18-May-2021 showing PCD C6-7 with
left foraminal occlusion. There is less LBP
with right sciatica. The patient is a known diabetic
under treatment for 6 years. She has a lot of
sensitivity panel to many drugs, for what this
list of sensitivity must be respected.
On examination: The patient in agonizing pain,
limping with normal stance. SLRS was 30 degrees with pain
both sides. There is weak dorsiflexion right
foot 4/5. The patient has pain when turning the
head to all directions. There is weak grip, extension
left
hand -3/5 and left triceps muscle -3/5 with
analgesia left median distribution. Edema of
four limbs is noted because she cannot sleep for
several days.
The patient was sent for
investigations and MRI under G.A. performed
14-July-2021 of the cervical spine showed
extruded disc C6-7 with left foraminal occlusion
and bulge disc L4-5. Tendinosis of the
subscapularis is noted with minimal subcoracoid
and glenohumeral effusion of the left shoulder.
Through anterior approach,
the level of C6-7 was identified and discectomy
of C6-7 was performed and the pieces compressing
the left side extradurally were removed.
EOS
OSImplant 6x13x10 mm dimensions was applied. Routine closure of the
wound. The patient then was exposed to BPRF to
the left suprascapular nerve to alleviate the
pain in the frozen left shoulder.
Smooth postoperative recovery.
The power of the left upper limb improved.
She was sent to the ward.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .