Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
04-AUGUST-2002 TAMER ALI NUWARA 29 YEARS EXTRUDED DISC C5-6 RIGHT SIDE.
Anamnesis
The patient came to the clinic
01-July-2002 complaining of LBP with neck pain
with left upper and lower limbs pain with chest
pain both sides. The last 3 months exacerbation
of neck and right shoulder pain and numbness of
the left hand. 1997 suffered RTA with neck pain. MRI
cervical spine performed 26-May-2002 showing
huge extruded disc C5-6 with right foraminal
occlusion.
On examination: The patient has neck pain when
rotating the head to all directions. There is weak grip,
extension right hand 3/5 and the right triceps
muscle 3/5. There is hypalgesia of the median
distribution left hand.
Through anterior approach, using the C-arm the level of C5-6 identified
and discectomy with osteophytectomy was
performed until the dura was seen at the bottom
of the created disc space. The extruded pieces
to the right foramen were removed. The dura was
relax. Routine
closure of the wound.
Smooth postoperative recovery.
The power of the right upper limb normalized.
He was sent to the ward.
Follow Up
The patient came to the clinic 14-August-2002
with clean wound and full power of the upper
limb and no radicular pain, but still hypalgesia
thumb left hand.
the patient then came 30-November-2011
complaining of left sciatica with SLRS 85
degrees left side without pain and weak dorsiflexion left foot.
He want to travel to Saudi Arabia.
The patient then came 28-October-2013 telling
that he suffered RTA 4 months ago and got
fracture C1 and C2 and was operated elsewhere.
CT-scan of the area showing screws at lateral
masses of C2. He has also fracture ribs. He was
advised to keep in conservative treatment.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .