Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
18-NOVEMBER-2003 TAYSEER TAHER SULAYMAN 58
YEARS RECURRENT HUGE EXTRUSION L4-5 LEFT SIDE.
Anamnesis
The patient came to the clinic
05-November-2003 telling that he was operated at
Palestinian authority in April-2000 and
continued to complain of LBP with left
sciatica with numbness left foot. He is using
crutches for 8 weeks. He is hypertensive in
treatment for 2 years.
On examination: the patient is in agonizing
pain, limping with exaggerated scoliotic stance.
SLRS was 85 degrees left side with pain. There
is weak dorsi and planterflexion both feet with
hypalgesia left L5 and S1 root territories.
The patient was sent for investigation and MRI
lumbar spine performed the next day showing huge
recurrence of his L4-5 disc, more to the left.
Decompressive laminectomy
L4-5. Neurolysis of the left L5
root was achieved. The
extruded disc material of L4-5 was removed from
under the axilla, which was pushing laterally
the root by the huge extrusion. Left sided intradiscal cleaning L4-5 was achieved.
The patient was put in Reverse Trendelenburg
position with Valsalva maneuver and
hyperventilation. No CSF leak. A free fat was
harvested from the subcutaneous layer and
covered the exposed parts of the root. to
minimize postoperative scarring. Routine
closure of the wound. Smooth postoperative
recovery. The power of the left foot became
normal.
FOLLOW UP
The patient came to the clinic
30-November-2003 with clean wound
and no sensory, nor motor deficit.
The patient
then came 21-November-2010 complaining of LBP
without sciatica and sent for investigations and no
recurrence was noted. He was treated conservatively.
Comments
There is still an
estimated postoperative re-recurrence around 7%
because the disc space is still not completely
collapsed.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .