Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
08-DECEMBER-2003
WAFIQA HAMDY AL-LABABIDI 75 YEARS EXTRUDED DISC C3-4, 4-5, 5-6 WITH
SEVERE STENOSIS.
Anamnesis
The patient came to the clinic 19-July-2003
complaining of numbness both hands with neck
pain for several months with difficult walking.
The condition is progressing. The patient is a
known diabetic for 17 years and hypertensive for
18 years.
On examination: the patient has pain in the neck
when looking to right and up. There is
hypalgesia right upper limb and both limbs below
the knees. There is weak grip and extension both
hands and both triceps muscles. Weak dorsi and
planterflexion both feet more weak left.
The patient then came 08-November-2003 with MRI
cervical spine showing severe stenosis due to
extruded disc C3-4, 4-5 and C5-6.
Using C-arm, discectomy of
C3-4, C4-5 and C5-6 was done until the dura was
seen at the entire posterior border of the
bodies. Using 3 level cervical plate fusion of
C3-4-5-6 was done.
Routine closure of the wound.
Smooth postoperative recovery. The power of four
limbs became better.
FOLLOW UP
The patient came to the clinic 24-December-2003
with clean wound and the sensory deficit
regressed to the tip of the index finger right
hand and the dorsum of the right foot.
The patient came 13-November-2005 10 days after
suffering CVA. MRI of the brain done
05-November-2005 showing infarction right
parietal lobe. The patient now complaining of
LBP with weak dorsi and planterflexion both
feet. She was sent for cardio consultation and
thorough investigations.
Comments
The patient has
severe stenosis due to extruded disc C3-4, 4-5
and C5-6. Decompression and fixation is the best
solution for this situation.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .