Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
06-AUGUST-2007 WALEED AWWAD SALEM 22 YEARS RTA 2 WEEKS AGO
WITH CONTUSION OF THE LEFT INTERNAL CAPSULE AND MULTIORGAN INJURIES AND FRACTURE-DISLOCATION C7-D1
WITH PARAPLEGIA BELOW TH-5.
Anamnesis
The patient was admitted 10 days ago for
multiorgan injuries after RTA and was operated
for internal bleeding and put in ventilator.
Upon recovery from ventilation, it was noticed
that he had right lower limb plegia and CT-scan
performed showed brain edema and suggestion for
axonal injury of the left internal capsule was
put clinically. He had also weak right upper
limb more the proximal muscles. Fracture of the
D5 was suspected and confirmed by CT-scan, but
there was no gross displacement.
Upon activation of the patient 2 days ago, the
patient progressed dense paraplegia below Th 5.
MRI of the brain and the whole spine was
performed and confirmed the presence of damage
to the left internal capsule and presence of
severe fracture-dislocation of C7-D1.
The patient was operated the next day and after
reduction of C7 upon D1, discectomy of C7-D1 was
performed. The upper anterior part of the D1
body was badly destroyed. Using cervical
miniplate, fusion of C7-D2 was performed and the
chips of the fractured bone put back to place.
Another screw was used to fix the left part of
the more or less acceptable part of D1 body.
Smooth postoperative recovery. Neurologically
the same.
Comments
The patient has 2 causes of his neurologic
problem, the internal capsule and the hidden fracture
dislocation of C7-D1. Presence of minor fracture of D5 misled
and hided the presence of the major fracture-dislocation at
C7-D1 which is difficult to note in the usual X-rays. This later
caused the further neurologic deterioration upon his activation.
This case support the need for whole body MRI
of the patient in the early stage of the multiorgan trauma to
avoid such mistakes.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II in the run starting from 14-March-2020
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .