Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
17-SEPTEMBER-2003 WEJDAN ABDEL-QADER DAWOOD 54
YEARS HUGE PCD C5-6 WITH QUADRIPARESIS.
Anamnesis
The patient came to the clinic 02-September-2003
complaining of LBP and right sciatica for 3
years. Operated for right knee 5 months ago.
Hypertensive for 2 years, in treatment. MRI
lumbar done 26-September-2002 showing LCS L4-5.
On examination: the patient walking with aid,
limping with wide based legs gait. She has
tetraparesis four limbs with weak grip,
extension and triceps right upper limb 3/5.
Hoffman positive both sides. SLRS was 30 degrees
both sides with pain. Brisk KJ both sides with
Babinski positive with weak dorsiflexion
both feet more the right. All the muscles of the
lower limbs are weak.
The patient was sent to perform MRI
of the brain with contrast and MRI of the
cervical spine, which was done 14-September-2003
to show a very huge extruded disc C5-6 with
malacia of the spinal cord.
Discectomy of C5-6
was done until the dura was seen along all the
posterior aspects. All stages of surgery were
done under C-arm control.
Routine closure of the wound.
Smooth postoperative recovery. The power of the
four limbs improved.
FOLLOW UP
The patient
came to the clinic 29-September-2003 with clean wound
and the power of the four limbs improved, except the
drop left foot.
The patient
then came 17-December-2003 complaining of inability
to walk properly due to cramps of the right lower
limb with almost drop right foot.
The patient
then came several times with ups and downs then came
10-September-2005 with MRI lumbar spine showing
stenosis D9-10. L3-4, 4-5 and L5-S1.
Comments
The patient has extrusion
of C5-6 causing the tetraparesis. She mostly
suffered for more than 3 years, for what
recovery will not be dramatic. but at least to
stop deterioration.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .